Customization: | Available |
---|---|
Cooling Method: | Air Cooling |
Frequency Band: | High Frequency |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
item
|
Parameter details
|
Aperture range
|
Groove Angle +45 degrees ,50mm-1000mm
|
|
0-degree groove ,270-1200mm
|
|
-45 degree bevel 460-1300mm
|
50mm-1200mm aperture range
|
The outer bevel of the pipeline has the function of initiating arc in the waste area
|
Lift shaft travel
|
0-250mm
|
Fixed bevel Angle
|
Flame cut ±45
Hole diameter/cylinder diameter > 1/3 The degree of groove should be reduced accordingly
More than 100mm thickness The groove Angle is less than 15 degrees
|
Cutting speed
|
0-500mm/min
|
Cutting accuracy
|
±2mm (related to workpiece standard)
|
Rated power
|
60W
|
Power source
|
Ac 220V/50Hz
|